8
Setting control point II
Data Structure ASCII ESC [ <n> ) t
hex. 1B 5B <n> 29 74
dec. 27 91 <n> 41 116
Function This command triggers the release of an acknowledgement signal to the processor
interface if the last mechanical procedure was started in the printing unit and no error
has occurred at this point in time. The printer will return the same value of <n> with the
same command sequence as this command to PC as a response.
<n> = value freely definable by the application in the range 0 to 9999.
Controlling User LEDs
Data Structure ASCII ESC [ <n> * t
hex. 1B 5B <n> 2A 74
dec. 27 91 <n> 42 116
Function This command controls USER1 and 2 LED as shown below.
Dual station control USER1 LED USER2 LED
<n> = 0: deactivated; default value
<n> = 1: activated off off
<n> = 2: activated on off
<n> = 3: activated off on
<n> = 4: activated on on
The indication of USER1/2 LED by switching Auto Select I/F is prior to controlling by
this command.